Thanks for using the TrueNAS Community Edition issue tracker! TrueNAS Enterprise users receive direct support for their reports from our support portal.

Cannot configure MTU < 1492

Description

In the UI, there is an indication that MTU values must be between 68 and 9000. After entering 1420 in this field and clicking apply, message "Should be between 1492 and 9216" is dispalyed, and the MTU is not set.

Problem/Justification

None

Impact

None

SmartDraw Connector

Katalon Manual Tests (BETA)

Activity

Show:

Bug Clerk January 6, 2021 at 4:45 PM

Stephen Cluff December 23, 2020 at 8:05 PM

This commit appears to adjust minimum MTU configurable in the GUI to 1492. This is pretty common for PPPoE setups, but lower MTUs are valid, and sometimes need to be configured for encapsulated tunnels where PMTU discovery and MSS clamping cannot be configured.

Bug Clerk December 23, 2020 at 2:34 PM

Complete