Protopia February 28, 2024 at 8:01 PM
According to this netdata documentation you add the following line to usr/lib/netdata/conf.d/python.d/smart_log.conf:
The tooltip for the Smart service Check Interval
should also probably say something about not going above 30mins or 60 mins
Protopia February 28, 2024 at 5:11 PM
Firstly a HUGE thank you to who has just spent about an hour looking at this (despite me being a free user!!!!!) - and it now appears to be working.
It appears to be due to one or both of the following settings in the Systems Settings
/ Services
/ Smart
settings:
Check interval - was set to 60 - but the SmartMonitoringTools require an interval <= 30 mins.
Power mode - set to
sleep
(when I was previously considering spinning down the HDDs overnight) but tooltip says it must be set to “Never”.
Anyway, changing these made it work.
That said, I suspect that it was item 1. of the two - because the Smart service settings are for the Smart service (which collects the data) rather than the SmartMonitoringTools service (which processes the data) and the data was being collected for all disks despite having Power mode set to sleep.
So, my primary concern - actual monitoring of the HDD temps in order to be warned about bearings overheating - is resolved. It would be beneficial for other users if either the 30 mins max interval was removed or the UI prevented the Check Interval to be set to more than 30.
My secondary and quite minor concern is that the USB SSD is not showing in graphs despite the SMART data being collected. But I can certainly live without that.
Once again - a HUGE thank you to Muhammad for his help (and patience).
Protopia February 28, 2024 at 2:58 PMEdited
4pm works for me. Sending credentials in a few mins.
P.S. I am assuming you mean Microsoft Teams - if yo mean something else please provide details.
Muhammad Rehan February 28, 2024 at 1:35 PM
does 4 PM GMT today works for you and if yes - please share teamviewer creds to my email a few minutes before 4 PM GMT..do let me know though please that the timing works for you
Protopia February 27, 2024 at 8:15 PM
This is why I stated the time of my comment - so that you could compare it with the local time of the comment as reported by Jira and calculate accordingly. I am in Western European Time which is the same as the UK and is GMT (for the next few weeks anyway).
After the upgrade to TrueNAS Scale version 23.10.2, the disk temperature for my SATA SSDs and Disks is still missing. There was already a call for this NAS-127100: SATA/SAS Disk Temps Missing Still in Cobia 23.10.1.1 and 23.10.1.3Fertig, and it says it’s fixed for 23.10.2, but still no temperatures are shown. Only for a single NVME drive. The System has 3 SATA SSDs and 2 SATA HHDs.