Description

I added/configured MinIO Enterprise SNMD HTTP on the M50g1-115.dc1.ixsystems.net running ElectricEel-24.10-RC.1-INTERNAL.3

The first time I accessed Minio using the Web UI button it opened a browser window to 0.0.0.0:30001
I corrected the IP to 10.220.16.85:30001 and it now works.
I talked to Grace and she also had that issue

Staveros also had the issue and asked me to put a ticket in for it

Steps to Reproduce

Configure MinIO Enterprise SNMD HTTP Once it is running, click the Web UI button

Expected Result

The browser window to open to http://10.220.16.85:30001/

Actual Result

The browser window opened to http://0.0.0.0:30001/ Once I correct the IP address it opens correctly and the correction persists.

Environment

None

Hardware Health

None

Error Message (if applicable)

None

Attachments

2

is duplicated by

Activity

Show:

Bug Clerk October 2, 2024 at 12:07 PM

This issue has now been closed. Comments made after this point may not be viewed by the TrueNAS Teams. Please open a new issue if you have found a problem or need to re-engage with the TrueNAS Engineering Teams.

Bug Clerk October 2, 2024 at 8:21 AM

Bug Clerk September 30, 2024 at 12:19 PM

Stavros Kois September 25, 2024 at 9:57 AM

note that the host can be a custom domain, eg cloud.example.com Currently is not implemented on my side, for any apps, but will be added. So do that only if host is 0.0.0.0

Ievgen Stepanovych September 23, 2024 at 10:14 AM

http://0.0.0.0:30001/ is received in portals in app.query collection change event.

Complete
Pinned fields
Click on the next to a field label to start pinning.

Details

Assignee

Alex Karpov

Reporter

Bonnie Follweiler

Story Points

0.5

Time remaining

0m

Original estimate

0m

Components

Priority

Medium

Katalon Platform

Created September 19, 2024 at 4:26 PM
Updated October 5, 2024 at 11:45 AM
Resolved October 2, 2024 at 12:07 PM