Gui Bug after invalid cron smart setting
Description
Problem/Justification
Impact
Attachments
Activity

Ievgen Stepanovych February 24, 2025 at 8:12 PM
My previous message has contained incorrect methods to call. I have since updated my comment.

Ievgen Stepanovych February 24, 2025 at 8:04 PMEdited
This should be fixed in and prevented in
As a workaround to make UI usable again, you can remove smart test task through shell:
Execute:
midclt call smart.test.query | jq
Remember the id of the task you want to remove.
Delete the task
midclt call smart.test.delete 2
.

Bonnie Follweiler February 24, 2025 at 6:45 PM
Good afternoon .
I have moved this ticket into our queue to review now.
An engineering representative will update with any further questions or details in the near future.

Niklas Blank February 23, 2025 at 2:48 PM
Just fyi: I updated from latest version of Dragonfish to Electric Eel just to see if this would fix the bug. It did not. Just so you know it is NOT only an issue in EE (24.10) but also in previous versions (at least 24.04).

Bug Clerk February 23, 2025 at 2:44 PM
No debug files were found.
Details
Details
Assignee

Reporter

I somehow got a invalid setting in my Smart schedule for cron. Therefore my entire Page "Data-Protection" does not work anymore. I can not push any button or change any setting. As you can see in the pictures below, the smart schedule which is responsible for the issue is not editable anymore, so i can not fix it. If I change or delete /etc/smartd.conf it gets reset after reboot or restart of smartd service, with no change before or after. Therefore the system is not usable anymore since i cannot change replication tasks in this page nor can I configure the smart schedule to run again properly.
Session ID: 5193c217-5fca-7189-6d3d-5197fa1b82b2